GB-GS Canopy

Central lifting point / Roof mounted lifting plates Compact design with integrated plastic fuel tank Exhaust silencer with rain flap Coolant refilling facility

Browse Categories

Filters

GBW15 canopy BIG.jpg - [504]

GBW15Y

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 13.67 kVA
PRIME POWER PRP: 12.81 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Stage V
ALTERNATOR: Mecc Alte

See details

GBW15 canopy BIG.jpg - [504]

GBW15Y

FREQUENCY: 60 Hz
VOLTAGE: 208 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 15.10 kVA
PRIME POWER PRP: 14.60 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GSW15P CANOPY A BIG (1).jpg - [1317]

GSW15P

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 14.31 kVA
PRIME POWER PRP: 12.91 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Unregulated
ALTERNATOR: Mecc Alte

See details

GSW15P CANOPY A BIG (1).jpg - [1317]

GSW15Y

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 13.67 kVA
PRIME POWER PRP: 12.81 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Stage V
ALTERNATOR: Mecc Alte

See details

GBW15 Other version from 400 DSE.jpg - [85916]

GBW-15P

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 12.07 kVA
PRIME POWER PRP: 10.94 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Unregulated
ALTERNATOR: Mecc Alte

See details

GBW15 canopy BIG.jpg - [504]

GBW-15P

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 10.72 kVA
PRIME POWER PRP: 9.67 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Unregulated
ALTERNATOR: Mecc Alte

See details

GBW15 Other version from 400 DSE.jpg - [85916]

GBW-15Y

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 11.02 kVA
PRIME POWER PRP: 10.45 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Unregulated
ALTERNATOR: Mecc Alte

See details

GBW15 canopy BIG.jpg - [504]

GBW15P

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 10.00 kVA
PRIME POWER PRP: 9.53 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Unregulated
ALTERNATOR: Mecc Alte

See details

GBW15.jpg - [279]

GBW15Y

FREQUENCY: 50 Hz
VOLTAGE: 400 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 13.67 kVA
PRIME POWER PRP: 12.81 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Stage V
ALTERNATOR: Mecc Alte

See details

GSW15P CANOPY A BIG (1).jpg - [1317]

GSW15P

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 10.00 kVA
PRIME POWER PRP: 9.53 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Unregulated
ALTERNATOR: Mecc Alte

See details

8 / 48