GB-GS Canopy

Central lifting point / Roof mounted lifting plates Compact design with integrated plastic fuel tank Exhaust silencer with rain flap Coolant refilling facility

Browse Categories

Filters

GSW10P CANOPY A BIG (1).jpg - [522]

GSW10Y

FREQUENCY: 60 Hz
VOLTAGE: 220 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 11.27 kVA
PRIME POWER PRP: 10.17 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GSW10P CANOPY A BIG (1).jpg - [522]

GSW10Y (Alt. LS)

FREQUENCY: 50 Hz
VOLTAGE: 230 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 8.94 kVA
PRIME POWER PRP: 8.42 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Stage V
ALTERNATOR: Leroy Somer

See details

GBW10 canopy BIG.jpg - [252]

GBW10P

FREQUENCY: 60 Hz
VOLTAGE: 240 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 9.22 kVA
PRIME POWER PRP: 8.33 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Tier 4 Interim
ALTERNATOR: Mecc Alte

See details

GBW10 canopy BIG.jpg - [252]

GBW10Y

FREQUENCY: 60 Hz
VOLTAGE: 240 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 8.33 kVA
PRIME POWER PRP: 7.52 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GSW10P CANOPY A BIG (1).jpg - [522]

GSW10P

FREQUENCY: 60 Hz
VOLTAGE: 240 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 10.70 kVA
PRIME POWER PRP: 10.00 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Tier 4 Interim
ALTERNATOR: Mecc Alte

See details

gsw10.jpg - [555]

GSW10P (Alt. LS)

FREQUENCY: 50 Hz
VOLTAGE: 400 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 9.67 kVA
PRIME POWER PRP: 8.74 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[50HZ] EXHAUST EMISSION LEVEL: Unregulated
ALTERNATOR: Leroy Somer

See details

GSW10P CANOPY A BIG (1).jpg - [522]

GSW10Y

FREQUENCY: 60 Hz
VOLTAGE: 240 V
PHASE: 1
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 8.33 kVA
PRIME POWER PRP: 7.52 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GBW10 canopy BIG.jpg - [252]

GBW10P

FREQUENCY: 60 Hz
VOLTAGE: 380 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 12.50 kVA
PRIME POWER PRP: 11.29 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Tier 4 Interim
ALTERNATOR: Mecc Alte

See details

GBW10 canopy BIG.jpg - [252]

GBW10Y

FREQUENCY: 60 Hz
VOLTAGE: 380 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 11.29 kVA
PRIME POWER PRP: 10.20 kVA
ENGINE BRAND: Yanmar
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Non Emission Certified
ALTERNATOR: Mecc Alte

See details

GSW10P CANOPY A BIG (1).jpg - [522]

GSW10P

FREQUENCY: 60 Hz
VOLTAGE: 380 V
PHASE: 3
POWER RANGE: a) <25 kVA
EMERGENCY STANDBY POWER ESP: 12.50 kVA
PRIME POWER PRP: 11.29 kVA
ENGINE BRAND: Perkins
ENGINE COOLING SYSTEM: Water
[60HZ] EXHAUST EMISSION OPTIMIZED FOR EPA TIER (EPA): Tier 4 Interim
ALTERNATOR: Mecc Alte

See details